Engine speed control 1 — deactivate above vehicle speed

SOPS parameter ENGINE_SPEED_CTRL1_DEACT_ABOVE_VEHICLE_SPEED · seen in 70 SOPS files

What it controls

Vehicle speed above which the bodywork engine speed control (channel 1) is switched off, or the condition that ends it. It stops a body-requested engine speed from being held while the truck is driven at road speed — important for cranes and platforms, where engine speed control must only work stationary. Mobile bodies that need a constant engine speed while moving (spreaders, sweepers, mixers) set a value that covers their working speed, or use the parking-brake condition instead. The value should be aligned with the PTO vehicle-speed cut-out so the PTO and the engine speed control stop at the same point and the operator gets a consistent behaviour.

Possible values

5seen in 36 files
—
ParkingBrake seen in 34 files
—
<km/h>
Engine speed control is deactivated above this vehicle speed.
ParkingBrake
Engine speed control is only active while the parking brake is applied.

Related parameters

PTO EG1 — disengage above vehicle speed
BWE.PTO_EG1_DEACT_ABOVE_VEHICLE_SPEED
Without · <km/h> Read
Engine speed control 1 — accelerator pedal disable
BWE.ENGINE_SPEED_CTRL1_ACC_PEDAL_DISABLE
With · Without Read
Engine speed control 1 — change rate
BWE.ENGINE_SPEED_CTRL1_CHANGE_RATE
1000 · <rpm/s> Read
ENGINE SPEED CTRL3 RAMP SPD
BWE.ENGINE_SPEED_CTRL3_RAMP_SPD
1000
ENGINE SPEED CTRL3 REF SPD
BWE.ENGINE_SPEED_CTRL3_REF_SPD
500