Skip to content

PTO EG1 — disengage above vehicle speed

SOPS parameter PTO_EG1_DEACT_ABOVE_VEHICLE_SPEED · seen in 70 SOPS files

What it controls

Vehicle speed in km/h above which the EG1 power take-off is disengaged automatically. This is the parameter that separates stationary from mobile PTO applications: a crane or tail-lift chassis typically has a low value (5–10 km/h) so the body cannot be operated while driving, while a gritter, sweeper or mixer needs the value raised or set to Without so the PTO keeps running at road speed. It works together with the parking-brake dependency — if the parking brake dependency is active, the PTO will already disengage when the brake is released regardless of this speed. Always confirm the equipment supplier's maximum driving speed before raising it.

Possible values

Withoutseen in 70 files
No vehicle-speed cut-out — the PTO runs at any speed.
<km/h>
The PTO disengages when vehicle speed exceeds this value.

Frequently asked

Spreaders are operated at road speed, so the cut-out is normally Without or set to the maximum spreading speed stated by the body manufacturer. Keep the parking-brake dependency at Without as well.

Related parameters

PTO EG1 — parking brake dependency
BWE.PTO_EG1_PBRAKE_DEP
Without · With Read
PTO EG1 — disengage above engine speed
BWE.PTO_EG1_DEACT_ABOVE_ENGINE_SPEED
Without · <rpm> Read
PTO EG1 — indicator lamp
BWE.PTO_EG1_INDIC_LAMP
Without · With Read
PTO EG1 — engagement feedback
BWE.PTO_EG1_FEEDBACK
With · Without Read
PTO EG1 — reverse gear dependency
BWE.PTO_EG1_GEARBOX_IN_REVERSE_DEP
Without · With Read
PTO EG1 — engage only below engine speed
BWE.PTO_EG1_ACT_BELOW_ENGINE_SPEED
Without · <rpm> Read