PTO EG1 — reverse gear dependency
SOPS parameter PTO_EG1_GEARBOX_IN_REVERSE_DEP · seen in 70 SOPS files
What it controls
Decides whether engaging reverse gear disengages the EG1 power take-off. Refuse collectors, sweepers and spreader bodies are frequently operated while reversing, so the dependency is normally set to Without for them. Tippers and cranes, on the other hand, are safer with the PTO dropping out in reverse so the body cannot be operated while the truck backs up. The parameter only has an effect once the PTO is engaged; it does not block engagement by itself. If a customer complains that the body stops every time the driver selects reverse, check this value before looking for an electrical fault in the bodywork interface.
Possible values
Withoutseen in 70 filesReverse gear has no effect on the PTO.
WithSelecting reverse disengages the PTO.
Related parameters
PTO EG1 — gearbox neutral dependencyBWE.PTO_EG1_NEUTRAL_DEP |
Activate · Deactivate · Activate+Deactivate | Read |
PTO EG1 — parking brake dependencyBWE.PTO_EG1_PBRAKE_DEP |
Without · With | Read |
PTO EG1 — indicator lampBWE.PTO_EG1_INDIC_LAMP |
Without · With | Read |
PTO EG1 — external control via bodywork interfaceBWE.PTO_EG1_EXTCON_WITH |
Without · With | Read |
PTO EG1 — engagement feedbackBWE.PTO_EG1_FEEDBACK |
With · Without | Read |
PTO EG1 — engage only below engine speedBWE.PTO_EG1_ACT_BELOW_ENGINE_SPEED |
Without · <rpm> | Read |