Skip to content

PTO EG1 — engage only below engine speed

SOPS parameter PTO_EG1_ACT_BELOW_ENGINE_SPEED · seen in 70 SOPS files

What it controls

Upper engine-speed limit for engaging the EG1 power take-off. Gearbox-driven and some flywheel PTOs must be engaged close to idle so the clutch or dog engagement is not damaged; setting a value here makes the coordinator ignore the switch while the engine is revving above it. Once engaged, the PTO is no longer governed by this parameter but by the deactivation windows. Typical values are between 900 and 1200 rpm. Leave it at Without on PTOs with their own hydraulic clutch that tolerate engagement at any speed, and always cross-check with the raised idle value so the raised idle itself does not block the engagement.

Possible values

Withoutseen in 70 files
No upper engine-speed condition for engagement.
<rpm>
Engagement is only accepted while engine speed is below this value.

Related parameters

PTO EG1 — engage only above engine speed
BWE.PTO_EG1_ACT_ABOVE_ENGINE_SPEED
Without · <rpm> Read
PTO EG1 — disengage above engine speed
BWE.PTO_EG1_DEACT_ABOVE_ENGINE_SPEED
Without · <rpm> Read
PTO EG1 — indicator lamp
BWE.PTO_EG1_INDIC_LAMP
Without · With Read
PTO EG1 — engagement feedback
BWE.PTO_EG1_FEEDBACK
With · Without Read
PTO EG1 — reverse gear dependency
BWE.PTO_EG1_GEARBOX_IN_REVERSE_DEP
Without · With Read
PTO EG1 — activation type
BWE.PTO_EG1_ACT_TYPE
Manual · Remote · Manual+Remote Read