Skip to content

PTO EG1 — engage only above engine speed

SOPS parameter PTO_EG1_ACT_ABOVE_ENGINE_SPEED · seen in 70 SOPS files

What it controls

Lower engine-speed limit for engaging the EG1 power take-off. When a value in rpm is set, the coordinator refuses the engagement request while the engine runs below it — useful on hydraulic pumps that must not be loaded at idle, or where the customer wants the PTO engaged only at a raised idle. Without limits the PTO engages at any engine speed. This parameter is one of four windows (activate above/below, deactivate above/below) that together shape the operating envelope of the PTO; keep them consistent with the raised idle speed value so the driver is not asked to hold a speed the engine cannot reach on its own.

Possible values

Withoutseen in 70 files
No lower engine-speed condition for engagement.
<rpm>
The PTO can only be engaged when engine speed is above this value (e.g. 800).

Related parameters

PTO EG1 — engage only below engine speed
BWE.PTO_EG1_ACT_BELOW_ENGINE_SPEED
Without · <rpm> Read
PTO EG1 — disengage above engine speed
BWE.PTO_EG1_DEACT_ABOVE_ENGINE_SPEED
Without · <rpm> Read
Raised idle speed — set point
BWE.RAISED_IDLE_SPEED_VALUE
700 · <rpm> Read
PTO EG1 — indicator lamp
BWE.PTO_EG1_INDIC_LAMP
Without · With Read
PTO EG1 — engagement feedback
BWE.PTO_EG1_FEEDBACK
With · Without Read
PTO EG1 — reverse gear dependency
BWE.PTO_EG1_GEARBOX_IN_REVERSE_DEP
Without · With Read